Includes: CD with software, Cord management straps, USB cable, User manual. APC Back-UPS 350. Battery Backup & Surge Protector for Electronics and Computers.
- The most popular desktop UPS in the world! APC's Back-UPS® ES series is now 'greener' than ever. The ES 350 utilizes an ultra-efficient design that consumes less power during normal operation than any other battery backup in its class, saving you money on your electricity bill.
- User Manual Back-UPS™ Pro BR 1000/1350/1500 MS. 2 Back-UPS Pro BR 1000/1350/1500 MS Connect the Battery The UPS is shipped with the battery disconnected. Www.apc.com Search for “PowerChute Personal Edition” then click on “View Details” to.
® |
Back-UPS™
CS
350/500
Apc Battery Back Ups 350
User’s Manual
990-2085 2/01
4 Switch on the Back-UPS
Note: Allow the Back-UPS to charge for a full eight hours prior to use.
Press the push-button on the front panel of the BackUPS.
ON LINE
ON BATTERY
OVERLOAD
REPLACE BATTERY
Observe that the following events occur after pressing and releasing the push-button:
•The green On-Lineindicator flashes.
•The yellow On Battery indicator lights while the Self-Testis being performed.
•When Self-Testhas successfully completed, only the green On Line indicator will be lit.
•If the internal battery is not connected, (see Step 1 above) the green On Line indicator and red Replace Battery indicator will light. The BackUPS will also emit a chirping sound.
1 Placement / Power
Avoid placing the Back-UPS in:
•Direct sunlight
•Excessive heat
•Excessive humidity or in contact with fluids of any type
Plug the Back-UPS into a wall outlet, as shown.
Your computer’s power cord.
•The Back-UPS charges the internal battery any time it is connected to a wall outlet.
2 Connect Equipment to the Back-UPS
The rear panel of the Back-UPS consists of the following elements:
Battery Back Up Outlets (qty. of 3). These outlets provide battery back-up, surge protection, and Electro-magnetic Interference (EMI) filtering. In case of power outage, battery power is automatically provided to these outlets. Power (utility or battery) is not supplied to these outlets when the Back-UPS is switched Off. Connect a computer, monitor, and external disk or CD-ROM drive to these outlets.
Surge Only Outlet. This outlet is always On (when utility power is available) and is not controlled by the On/Off switch. This outlet does not provide power during a power outage. Connect a printer, fax machine or scanner to this outlet.
3 Connect the Phone Line to Surge Protection
The telephone ports provide lightning surge protection for any device connected to the telephone line (computer, modem, fax or telephone). The telephone ports are compatible with Home Phoneline Networking Alliance (HPNA) and Digital Suscriber Line (DSL) standards, as well as all modem data rates. Connect as shown.
Wall Outlet
Modem/Phone/Fax
5 Connect USB Cable and Install Software (optional)
Note: The Back-UPS software CD-ROM provides data reporting and unattended shutdown of computers connected to the device. The User’s Guide contains additional information about the Back-UPS software. The User’s Guide is contained in the main folder with the CD-ROM.
Attention: USB Hubs
The Back-UPS should be plugged into the USB port of the computer, not into a USB hub.
The computer must be powered On before connecting the USB cable. Connect the USB cable end (USB symbol facing down) to the rear panel USB port of the Back-UPS. Connect the other end of the USB cable to the USB port (usually located on the rear panel of the computer).
Windows 98® and Windows Me® Users
The APC Power Management Extensions software has been designed specifically to work with Windows 98 build number 4.10.1998, Windows 98 SE (Second Edition) 4.10.2222A, and Windows Me (Millennium Edition).
To ascertain the build number, go to the Control Panel, open the System dialog and view the System information under the General tab of the dialog. To install the software, perform the following steps:
1.Please skip to step 4 if running Windows Me. For Windows 98, after connecting the USB cable, the “Add New Hardware Wizard” dialog box is displayed. Insert a Windows 98 operating system CD into the computer CD-ROM drive before proceeding.
2.Follow the installation instructions on the computer screen.
During installation, Windows will need to search for new drivers. When prompted, make sure the CD-ROM drive box is checked.
3.After installation of the drivers is complete, a “Windows 98 CD-ROM” dialog box may appear. If this happens, just close the box.
4.Insert the APC Installation CD-ROM into the computer’s drive. The software user documentation is a file on the main folder of the CD. The filename is Users Guide.pdf.
5.Follow the installation instructions on the computer screen.
If the software does not automatically install, the Windows autorun feature may have been disabled. In this case: Choose “Start” in the taskbar and then the “Run” option. Type the following: <CD-ROM drive letter>:setup.exe. Click “OK”.
6.After the installation is complete, the APC plug icon will appear in the taskbar (near the clock). To view the Power Management user interface, double-click on the APC plug taskbar icon or, alternatively, choose: Start > Settings > Control Panel > Power Management.
Note: Windows 98 and Windows Me categorize a UPS as an HID (Human Interface Device). The Back-UPS is listed in: Control Panel > System > Device Manager > HID category > HID Compliant Device.
Windows 2000® Users
The CD-ROM included with this package contains a “wizard” that optimizes a computer system’s power settings for operation with the Back-UPS. It does this by changing various settings in Power Options Properties in the Control Panel. APC strongly advises that the computer system be reconfigured by running this wizard.
1.Insert the APC Power Management CD-ROM into the computer’s drive.
2.Choose “Start” and then the “Run” option. Type: <CD-ROM drive letter>:setup.exe.
Mac OS 9 (9.0.4 or higher) Users
APC Shutdown Manager software has been designed specifically to work with Mac OS 9 (9.0.4 or higher, except OS X). There are builds of the Mac OS prior to Mac OS 9.0.4 with power drivers that have known problems. Ensure that the most up to date version of Mac OS 9 (9.0.4 or higher) is installed on the system.
Insert the APC Installation CD-ROM with the APC Shutdown Manager software into the CD-ROM drive. An icon called “APC Shutdown Manager v1.0” will appear on the computer desktop. Open the folder and double-click the “ReadMe” file. Ensure that the computer’s hardware matches the requirements stated in the ReadMe file. Double-click on “APC Shutdown Manager v1.0” to begin the installation of the software. At the first dialog, click on “Continue”. Read the displayed license agreement and click “Accept” to agree to the terms. Click on “Install” to begin. After installation, click on the “Restart” dialog button to restart the computer.
All Other Users
The software is designed for the Windows and Macintosh operating systems mentioned in this section. If one of these operating systems is not installed on the computer, the Back-UPS will still provide these primary features:
•Battery backup, surge protection, and telephone line protection to protect the entire desktop from lightning and power surges.
•Runtime needed to work through brief power disturbances. This allows time to manually save data and shut down safely.
Apc Back Ups 350 User Manual Pdf
The disabled features include Unattended Automatic Operating System Shutdown and Application Data Saving.
Status Indicators and Alarms | Replace the Internal Battery |
There are four status indicators (lights) on the front panel of the Back-UPS (On Line, On Battery, Overload, and Replace Battery).
ON LINE
ON BATTERY
OVERLOAD
REPLACE BATTERY
On Line (green) - is lit whenever utility power is powering the Battery Backup outlets.
On Battery (yellow) - is lit whenever the battery of the Back-UPS is powering equipment connected to the Battery Backup Outlets.
Four Beeps Every 30 Seconds - this alarm is sounded whenever the BackUPS is running On Battery. Consider saving work in progress.
Continuous Beeping - this alarm is sounded whenever a low battery condition is reached. Battery run-time is very low. Promptly save any work in progress and exit all open applications. Shutdown the operating system, computer and the Back-UPS.
Overload (red) - is lit whenever power demand has exceeded the capacity of the Back-UPS.
Continuous Tone - this alarm is sounded whenever the Battery Backup outlets are overloaded.
Circuit Breaker - the circuit breaker button located on the rear panel of the Back-UPS will stick out if an overload condition forces the Back-UPS to disconnect itself from utility power. If the button sticks out, disconnect nonessential equipment. Reset the circuit breaker by pushing the button inward.
Apc Back Ups 350
Replace Battery (red) - is lit whenever the battery is near the end of its useful life, or if the battery is not connected (see above). A battery that is near the end of its useful life has insufficient runtime and should be replaced.
Chirps for 1 Minute Every 5 Hours - this alarm is sounded whenever the battery has failed the automatic diagnostic test.
To replace the internal battery, proceed as follows:
Note: Replacing the battery is a safe procedure. However, small sparks may occur during the process. This is normal.
1 | 2 |
Place the unit on its side. Slide the battery | Pull the battery out, exposing the battery terminals | ||
compartment cover upward and off of the UPS. | and wires. Disconnect the wires from the terminals. | ||
3 | 4 |
Slide the new battery into the battery compartment. | Align the battery compartment cover with the grooves |
Connect the battery wires to the terminals as follows: | in the UPS. Slide the cover down until it locks. |
Black wire to Ground (-) terminal | |
Red wire to Positive (+) terminal |
APC, Back-UPS, and PowerChute plus are registered trademarks of American Power Conversion. All other trademarks are property of their respective owners.
Includes: CD with software, Cord Management Straps, USB cable, User Manual
List Price:
Our Price: $94.99
Overview:
Key Features:
- Serial Connectivity
- USB connectivity
The re-invention of the most relied upon desktop UPS in history: the Back-UPS!
The Back-UPS CS offers our best value for protecting your business and office computer systems. It provides battery backup power that allows you to work through short and medium length power outages. It also safeguards your equipment from damaging surges and spikes that travel along your utility and phone lines. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like Audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and Transformer-block spaced outlets make the Back-UPS CS the perfect unit to protect your business' productivity from the constant threat of power outages and lost data.
Features & Benefits:
Protection | |
Battery-protected and surge-only outlets | Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment |
Power conditioning | Protects connected loads from surges, spikes, lightning, and other power disturbances. |
Dataline Surge Protection | Provides protection of connected equipment from power surges on the data lines. |
Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |
Convenience | |
Audible alarms | Provides notification of changing utility power and UPS conditions. |
Automatic restart of loads after UPS shutdown | Automatically starts up the connected equipment upon the return of utility power. |
Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Battery replacement without tools | Provides reduced risk of load disruption by allowing quick and easy battery replacement. |
LED status indicators | Quickly understand UPS status with indicators. |
Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
Resettable circuit breakers | Enables quick recovery from UPS overload events. |
Transformer-block spaced outlets | Protect equipment with input transformer blocks without blocking access to other receptacles. |
User-replaceable batteries | Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
Runtime Chart:
120V | |||||||||||
Watts | 50 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | Full | Half |
VA~ | 80 | 160 | 320 | 480 | 640 | 800 | 960 | 1120 | 1280 | Load | Load |
BK350 | 47 min | 19 min | 5 min | - | - | - | - | - | - | 5 min (210 Watts) | 18 min (105 Watts) |
BK500 | 1 hrs 2 mins | 26 min | 8 min | 2 min | - | - | - | - | - | 2 min (300 Watts) | 14 min (150 Watts) |
BK500BLK | 1 hrs 2 mins | 26 min | 8 min | 2 min | - | - | - | - | - | 2 min (300 Watts) | 14 min (150 Watts) |
Technical Specifications:
Output | |
Output Power Capacity | 210 Watts / 350 VA |
Max Configurable Power | 210 Watts / 350 VA |
Nominal Output Voltage | 120V |
Waveform Type | Stepped approximation to a sinewave |
Output Connections | (3) NEMA 5-15R (Battery Backup) (3) NEMA 5-15R (Surge Protection) |
Input | |
Nominal Input Voltage | 120V |
Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
Input Connections | NEMA 5-15P |
Cord Length | 6 feet (1.83 meters) |
Input voltage range for main operations | 98 - 140V |
Batteries & Runtime | |
Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof |
Typical recharge time | 8 hour(s) |
Replacement battery cartridge | RBC2 |
RBC™ Quantity | 1 |
Typical Backup Time at Half Load | 18.1 minutes (105 Watts) |
Typical Backup Time at Full Load | 4.7 minutes (210 Watts) |
Runtime Chart | Back-UPS CS |
Communications & Management | |
Interface Port(s) | DB-9 RS-232,USB |
Control Panel | LED status display with On Line : On Battery : Replace Battery and Overload indicators |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering | |
Surge Energy Rating | 1020 Joules |
Filtering | Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Dataline Protection | RJ-11 Modem/Fax/DSL protection (two wire single line) |
Physical | |
Maximum Height | 6.50 inches (165 mm) |
Maximum Width | 3.60 inches (91 mm) |
Maximum Depth | 11.20 inches (284 mm) |
Net Weight | 12.50 lbs. (5.68 kg) |
Shipping Weight | 14.00 lbs. (6.36 kg) |
Shipping Height | 10.35 inches (263 mm) |
Shipping Width | 6.89 inches (175 mm) |
Shipping Depth | 14.06 inches (357 mm) |
Master Carton Units | 2.00 |
Master Carton Weight | 29.00 lbs. |
Color | Beige |
SCC Codes | 1073130401629 5 |
Units per Pallet | 80.00 |
Environmental | |
Operating Environment | 32 - 104°F (0 - 40°C) |
Operating Relative Humidity | 0 - 95% |
Operating Elevation | 0-10000 feet (0-3000 meters) |
Storage Temperature | 5 - 113°F (-15 - 45°C) |
Storage Relative Humidity | 0 - 95% |
Storage Elevation | 0-50000 feet (0-15000 meters) |
Audible noise at 1 meter from surface of unit | 45.00 dBA |
Online Thermal Dissipation | 20.00 BTU/hr |
Conformance | |
Regulatory Approvals | FCC Part 68,TUV |
Standard Warranty | 3 years repair or replace |
Equipment protection policy | Lifetime: $100,000 |
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.
Documentation:
Download the APC BK350 Data Sheet (PDF).
Pricing Notes:
- Pricing and product availability subject to change without notice.
- Note: Shipping charges may vary depending on the selected unit's weight or the quantity of units selected. As a result, the shipping charges may change from the value you receive at checkout. A customer representative will confirm these changes with you if they occur before processing your order.
List Price:
Our Price: $94.99
List Price:
Our Price: $39.99
Apc 350 Ups
List Price:
Our Price: $49.99
List Price:
Our Price: $59.99
Apc Back Ups Es 350 Manual
List Price:
Our Price: $44.99
List Price:
Our Price: $89.99
List Price:
Our Price: $49.99
List Price:
Our Price: $109.99